Air Cooled Condenser Structure, Heat Dissipation Principle & Application Scenarios

Air cooled condenser exchanges heat between high-temperature refrigerant gas and ambient air; refrigerant condenses into liquid and releases heat. Main components: copper tube with aluminum fin, axial fan, header, liquid subcooling section, metal frame, fan guard. Ambient air blows across fin coil, takes away condensation heat; no water consumption, simple maintenance, widely used for export cold room. Key performance index: design ambient temperature, approach temperature; high ambient area directly reduces condensation efficiency. Xiteliduo air cooled condenser supports R404A/R507/R448A/R449A, optional EC energy-saving fan for overseas projects. Condenser installation must guarantee unobstructed air inlet and outlet; hot air recirculation is the top cause of high pressure alarm. Fan configuration: single speed, dual speed or EC variable speed; EC fan adjusts speed according to condensing pressure to save power. Fin surface dust, cotton, debris accumulation forms thermal resistance, condensing pressure rises and unit power consumption increases. Salt spray coastal area needs anti-corrosion treatment: epoxy coated fin or aluminum fin hydrophilic anti-corrosion coating. Refrigeration maintenance & repair company checks condensing pressure, fan running current and fin cleanliness regularly.

FAQ

  1. What is the heat exchange medium of air cooled condenser? Ambient air.
  2. What is the common fin and tube material? Copper tube + aluminum fin.
  3. What is the main advantage of air cooled condenser? No water needed, easy maintenance.
  4. What fault will hot air recirculation cause? High condensing pressure and high pressure protection.
  5. Which fan type can adjust speed by condensing pressure? EC fan.
  6. What upgrade for coastal salt spray environment? Epoxy coated anti-corrosion fin.
  7. What problem if fin is covered with dust? Heat dissipation drops, power consumption rises.
  8. Where should condenser hot air discharge avoid blowing back? Condenser air intake side.
この記事のURL: https://ja.xtldcool.com/news/844.html

オンラインで製品のカスタマイズプランを入手する

以下の欄に必要事項をご記入いただければ、無料で入手できます。

相談ホットライン

+86-18157593311

Xiteliduo & Chuanli

R32半密閉型ピストンコンプレッサーおよびカスタムメイドのターンキー式産業用冷凍システムの中国直営工場。自社開発のコンプレッサーと包括的な冷凍ソリューションにより、熱帯地域や極低温の動作環境においても安定した性能を発揮します。

お問い合わせ

技術サービス:+86-575-83665888;83068555 
コンプレッサーホットライン:+86-18157593311 
電気ヒーターチューブホットライン:+86-13857577938 
Eメール:helenliu1983xtld@gmail.com 
電気加熱管工場:紹興市嵊州市甘林鎮東湖村150号 
コンプレッサー工場:紹興市嵊州市東国経済開発区679号

Copyright © 2026 浙江西特利多環境技術有限公司および嵊州市川利環境技術有限公司。無断転載・複製を禁じます。