Water Cooled Condenser, Shell & Tube Type, Cooling Water Circuit & Water Quality Requirement

Shell and tube water cooled condenser: high pressure refrigerant gas outside tubes, cooling water flows inside copper tubes for heat exchange. Heat transfer efficiency is higher than air cooled type, stable condensing temperature, suitable for large rack unit and high heat load. Cooling water takes heat away and flows to cooling tower for re-cooling; water system needs water pump, pipeline, water treatment. Water quality control is critical: high hardness water causes scale attached on inner tube wall, heat transfer capacity drops sharply. Xiteliduo shell and tube condenser adopts seamless copper tube, can be matched with open type or closed cooling tower. Water flow rate must keep within design range; insufficient water flow leads to high condensing pressure; excessive flow wastes pump power. Water side chemical cleaning is required periodically; scale, slime and algae are hard to remove once thickened. Winter low ambient region needs water circuit anti-freeze: drain water, add antifreeze or install tracing heating cable. Water cooled system has more auxiliary equipment, higher initial investment and maintenance cost than air cooled solution. Refrigeration maintenance & repair company monitors water inlet/outlet temperature difference to judge fouling degree.

FAQ

  1. What is the mainstream structure of water cooled condenser? Shell and tube type.
  2. Which medium flows inside the tube? Cooling water.
  3. What is the advantage of water cooled condenser? Higher heat exchange efficiency, stable condensing pressure.
  4. What is the main hazard of hard cooling water? Scale formation on inner tube wall.
  5. What equipment is needed to cooperate with water cooled condenser? Cooling tower and water circulation pump.
  6. How to judge water side fouling? Water temperature difference becomes smaller than design value.
  7. What protection for water circuit in cold winter? Drain water, antifreeze liquid or heat tracing.
  8. What is the disadvantage of water cooled system? Extra water system investment and maintenance work.
この記事のURL: https://ja.xtldcool.com/news/843.html

オンラインで製品のカスタマイズプランを入手する

以下の欄に必要事項をご記入いただければ、無料で入手できます。

相談ホットライン

+86-18157593311

Xiteliduo & Chuanli

R32半密閉型ピストンコンプレッサーおよびカスタムメイドのターンキー式産業用冷凍システムの中国直営工場。自社開発のコンプレッサーと包括的な冷凍ソリューションにより、熱帯地域や極低温の動作環境においても安定した性能を発揮します。

お問い合わせ

技術サービス:+86-575-83665888;83068555 
コンプレッサーホットライン:+86-18157593311 
電気ヒーターチューブホットライン:+86-13857577938 
Eメール:helenliu1983xtld@gmail.com 
電気加熱管工場:紹興市嵊州市甘林鎮東湖村150号 
コンプレッサー工場:紹興市嵊州市東国経済開発区679号

Copyright © 2026 浙江西特利多環境技術有限公司および嵊州市川利環境技術有限公司。無断転載・複製を禁じます。