ニュース

Closed Cooling Tower, Dry-Wet Mode & Application for High Standard Refrigeration Project

  • 彼らの分類:
  • ビュー: ...
  • 解放時間: 2026-10-31

Closed Cooling Tower, Dry-Wet Mode & Application for High Standard Refrigeration Project

Closed cooling tower, also called closed circuit cooling tower: refrigerant water circulates inside coil, not directly contact with air. Spray water wets outer coil surface for evaporative cooling; circulating cooling water of condenser is isolated inside coil. Two working modes: wet mode (spray on) for high heat load; dry mode (spray off) for low ambient, no water evaporation. Core advantage: cooling water circuit is closed, no dust and algae pollution, greatly reduce scaling risk of condenser tube. Xiteliduo closed cooling tower is preferred for food factory, pharmaceutical cold storage and projects with strict water requirement. Closed tower cost is higher than open tower; coil outer surface will also scale gradually on spray side and needs cleaning. Dry mode running can save water and reduce water treatment workload in spring, autumn and winter. Anti-freeze design for closed tower: water basin heating, automatic drain valve or add antifreeze for spray water loop. Closed tower occupies smaller auxiliary water treatment equipment, suitable for areas with poor water quality. Refrigeration maintenance & repair company distinguishes coil side fouling and spray side fouling by temperature log.

FAQ

  1. What is the key feature of closed cooling tower? Process water is sealed inside coil, no direct contact with air.
  2. What are its two working modes? Wet mode and dry mode.
  3. What is the biggest advantage compare with open tower? Water circuit clean, less scaling of condenser.
  4. Which project prefers closed cooling tower? Food and pharmaceutical cold storage.
  5. What is the disadvantage of closed cooling tower? Higher procurement cost.
  6. What is the cooling medium outside coil in wet mode? Spray water film evaporation.
  7. Can closed tower run without spray water? Yes, dry cooling mode.
  8. Where does scaling easily occur on closed tower? Outer surface of heat exchange coil.
この記事のURL: https://ja.xtldcool.com/news/841.html

オンラインで製品のカスタマイズプランを入手する

以下の欄に必要事項をご記入いただければ、無料で入手できます。

相談ホットライン

+86-18157593311

Xiteliduo & Chuanli

R32半密閉型ピストンコンプレッサーおよびカスタムメイドのターンキー式産業用冷凍システムの中国直営工場。自社開発のコンプレッサーと包括的な冷凍ソリューションにより、熱帯地域や極低温の動作環境においても安定した性能を発揮します。

お問い合わせ

技術サービス:+86-575-83665888;83068555 
コンプレッサーホットライン:+86-18157593311 
電気ヒーターチューブホットライン:+86-13857577938 
Eメール:helenliu1983xtld@gmail.com 
電気加熱管工場:紹興市嵊州市甘林鎮東湖村150号 
コンプレッサー工場:紹興市嵊州市東国経済開発区679号

Copyright © 2026 浙江西特利多環境技術有限公司および嵊州市川利環境技術有限公司。無断転載・複製を禁じます。