ニュース

Cold Room Panel Tongue & Groove Joint, Sealing Method & Thermal Break Design

  • 彼らの分類:
  • ビュー: ...
  • 解放時間: 2026-10-31

Cold Room Panel Tongue & Groove Joint, Sealing Method & Thermal Break Design

Tongue and groove joint is the connecting structure between adjacent PU panels; sealing failure is No.1 hidden heat leakage point of assembled cold room. Standard interlock: male-female tongue groove, filled with continuous PU foam during production; on-site secondary seal uses neutral silicone sealant. Two sealing layers: inner side food-grade silicone for cold room interior; outer weatherproof silicone for outside face, prevent air and moisture penetration. Ordinary tongue groove without thermal break: under big inside-outside temperature difference, metal bridge conducts heat and causes groove frost. Thermal break tongue groove inserts non-metal isolation strip to cut metal heat bridge, widely used for -25℃ below low temp and blast freezer panels. Xiteliduo cold room PU panel HS 940600 offers standard joint and thermal break joint options for different temperature grades. Panel vertical seam and horizontal seam must be sealed fully; broken seal at one small section will let moisture creep into foam and expand damage gradually. Sealant cannot be acid type; acid silicone corrodes steel sheet and contaminates food cold room environment, not allowed for food export audit. When installing, panel joint gap must be controlled ≤3mm; oversize gap cannot be filled well by sealant and becomes permanent leakage path. Refrigeration maintenance & repair company redoes seam sealing when recurring frost line appears along panel tongue and groove.

FAQ

  1. What is the standard connecting structure of cold room panel? Male-female tongue and groove interlock.
  2. How many sealing layers are required for panel joints? Inner food-grade silicone and outer weatherproof silicone, double seal.
  3. What is thermal break tongue groove for? Cut metal heat bridge and avoid frost on seams of low-temperature cold room.
  4. Which cold room needs thermal break joint priority? -25℃ and below frozen storage and blast freezer.
  5. Why acid silicone sealant is forbidden for cold room? Corrodes metal sheet and fails food factory inspection.
  6. What maximum allowable gap between two matched panels? ≤3mm.
  7. What happens if moisture enters panel foam through bad seal? Foam absorbs water, insulation drops and frost spreads along seam.
  8. What symptom indicates failed tongue groove sealing? Stable continuous frost line along panel joint.
この記事のURL: https://ja.xtldcool.com/news/861.html

オンラインで製品のカスタマイズプランを入手する

以下の欄に必要事項をご記入いただければ、無料で入手できます。

相談ホットライン

+86-18157593311

Xiteliduo & Chuanli

R32半密閉型ピストンコンプレッサーおよびカスタムメイドのターンキー式産業用冷凍システムの中国直営工場。自社開発のコンプレッサーと包括的な冷凍ソリューションにより、熱帯地域や極低温の動作環境においても安定した性能を発揮します。

お問い合わせ

技術サービス:+86-575-83665888;83068555 
コンプレッサーホットライン:+86-18157593311 
電気ヒーターチューブホットライン:+86-13857577938 
Eメール:helenliu1983xtld@gmail.com 
電気加熱管工場:紹興市嵊州市甘林鎮東湖村150号 
コンプレッサー工場:紹興市嵊州市東国経済開発区679号

Copyright © 2026 浙江西特利多環境技術有限公司および嵊州市川利環境技術有限公司。無断転載・複製を禁じます。